Similar to AHU, FCU is an air handling unit but has a simpler structure and smaller size. Currently, this device is widely used in air conditioning systems to provide cold or warm air for residential spaces, high-rise buildings or commercial projects. If you are interested What is FCU?, what is the structure and principle of this device, let's find out together Tan Long Follow the article below!
Find out what FCU is?
What is FCU? FCU stands for Fan-Coil Unit, an air handling unit commonly incorporated into HVAC (ventilation, heating and air conditioning) systems. FCU uses insulated flexible ductwork and is typically installed in residential buildings, commercial buildings or industrial facilities. Although similar to AHU in air handling, FCU has a simpler structure and is smaller in size.
FCU is designed to handle air with low capacity, usually only from 2kW-20kW. Popular types of FCU today include: round/4-way/1-way Cassette type, ceiling mounted, wall mounted, concealed, concealed, wall mounted, ducted ceiling, etc.

FCU Structure – Fan Coil Unit
After knowing what FCU is, let's learn about the structure of this device with Tan Long. The structure of FCU includes the following parts:
- Fan
- Coil
- Dust filter
- Engine
- Heat exchanger tube
- Condensate screen
In addition to these main components, some FCUs also have an electric heater. However, in Vietnam, this part is not commonly equipped in FCUs.

Popular FCU Types
There are currently 3 types of FCUs that are most commonly used today. These types of FCUs are selected based on the specific needs of each project and the characteristics of the space that needs to be cooled or heated.

FCU wall mounted, ceiling mounted, wall mounted
Condenser The FCU is typically mounted directly on a wall or ceiling. The unit is enclosed in a housing to protect and conceal components such as the fan coil and air diffuser.
FCU ceiling mounted duct connection, hidden ceiling, hidden wall
If the FCU is installed in the ceiling, the technician will work in the ceiling cavity or false ceiling. The two main devices installed in the ceiling are the grille and the air diffuser. This type is preferred because it takes advantage of the ceiling cavity for air circulation.
FCU Cassette round blow, 1-way type and 4-way type
These FCU types depend on the type of fan used.
What is the operating principle of FCU?

- During the heat transfer process, the coil in the FCU can increase or decrease the heat and receive hot or cold water from the central air conditioning system.
- Traditional fan coils can have a thermostat inside the FCU or be connected to operate with a remote controller.
- The fan inside the FCU is speed-controlled to cool or heat the air as needed.
- Some Fan Coil Unit modules regulate air speed by adjusting taps on the AC transformer that supplies power to the fan motor. However, this adjustment is usually only a fixed speed and is done during installation or construction.
- Some other modules are equipped with permanent capacitor motors, allowing users to adjust the fan speed as desired by customizing the levels in the coil.
What are the advantages and disadvantages of FCU?
What are the advantages of FCU?
- Compact and sturdy design: With a thickness of only 430mm, FCU still provides high air volume, suitable for office buildings, restaurants... with limited installation space.
- High heat exchange efficiency: FCU uses quality copper tubes and aluminum fins, combined with a metal-coated design to limit deformation during transportation and installation.
- Low noise: Although FCUs still generate some noise during operation, they are equipped with static and dynamic balance checks along with high-quality insulation and soundproofing, which reduces noise to a minimum.
- Easy maintenance: High quality electric motor and low noise bearing do not require lubrication, minimizing maintenance time. Fan blades and motor can be easily removed for cleaning the heat exchanger.
- Long life: The filter in the FCU is more efficient than conventional filters, extending the life of the equipment.
- No water leakage: The design of the condensate tray and heat exchanger with high working pressure prevents water leakage from the FCU.
- Flexible adjustment: FCU can flexibly adjust fan speed and temperature, helping to save energy and meet usage needs.
- High product quality: FCU is manufactured on high-tech production lines, meeting ISO and CE quality standards, ensuring product quality is always a priority.

What are the disadvantages of FCU?
So, what are the disadvantages of FCU? Besides the outstanding advantages mentioned above, FCU still has some disadvantages as follows:
- For the system to work effectively, a dedicated space is required.
- The system requires a low level of automation, and requires specialized management and supervision.
- Maintenance and servicing are not simple and require high technical skills when repairs are required.
FCU Installation Requirements and Instructions
Technical requirements when installing FCU
- Install rubber cushion between the suspension rod and the device to reduce vibration when the FCU is operating.
- The installation space must be large enough to facilitate operation and maintenance.
- Flexible duct and pipe connections must comply with design requirements, be leak tested and insulated to prevent moisture.
- The drain pipe must have a diameter not smaller than the design requirement and must be connected to the nearest drain pipe.
Detailed instructions when installing Fan Coil Unit
A thorough inspection before putting the system into operation is necessary to ensure the safety and efficiency of the system, avoiding unexpected problems and dangers. To install and operate the FCU correctly and effectively, the following steps must be followed:
Prepare for installation
- Use construction drawings to prepare in advance.
- Select equipment and accessories according to material and technical requirements.
- Make sure the work area is clean and well ventilated.
- Prepare all tools for installation process.
How to install
- Measure and mark the installation location before proceeding.
- Mark the FCU threaded rod hanging hole position and install the machine according to the determined position, then drill the hole and attach the hanging rod.
- Install related equipment.
- Install the required valve assembly.
- Ensure balance for Fan Coil Unit by adjusting anti-vibration spring.

Test run
- Before performing a test run, the entire electrical system must be checked and safety ensured.
- Carefully check the operating parameters and environmental conditions in the area of use.
- Measure noise and vibration of equipment.
- Measure temperature and humidity.
- Check electrical safety parameters for the system.
What is the practical application of FCU?
Nowadays, FCUs are widely used in apartment buildings, high-rise buildings, and commercial projects. In high-rise buildings, FCUs are often installed stacked vertically, from floor to floor, and connecting FCUs together through the same piping system.
In high-rise projects, FCUs are often mounted in the ceiling in bathrooms or used to provide cold air to areas that are not too large.

Hope the information that Tan Long The information provided above has helped you know what FCU is, the structure and operating principle of this device. If you have any questions, please comment below so Tan Long can help you answer!