TRUSTED PROVIDER OF GLYCOL CHILLER IN VIETNAM

Glycol water chiller is one of the solutions for industrial refrigeration systems today. With the ability to cool water and glycol solutions. Glycol chiller meets the refrigeration requirements for industries such as: food and beverage, medicine, chemicals and many other industries.
The coolant commonly used in water chillers is a mixture of water and another substance with suitable thermal conductivity properties – such as a glycol compound. Glycol-based coolants include ethylene glycol or propylene glycol. The main advantage of glycol coolants is their anti-freeze properties. Pure water freezes at 0 degrees Celsius. While ethylene glycol 30% freezes at -14 degrees Celsius. The low freezing point of glycol mixtures is suitable for cooling items below the freezing point of water. Although glycol has a lower heat capacity than water (each kilogram of glycol is easier to heat than a kilogram of water). The larger temperature difference allows glycol mixtures to remove heat faster than pure water. Glycol mixtures are better suited for applications where the chiller must remove large amounts of heat quickly.
TECHNICAL SPECIFICATIONS OF WATER CHILLER USING GLYCOL
| Device Name | Glycol water chiller |
| Form of cooling | Air cooled chiller and water cooled chiller |
| Origin | Manufacturer in Vietnam |
| Type | Use glycol antifreeze |
| Electric current | 3 phase 380-420V/50Hz |
| TAN power range LONG provided | From 5HP and up |
| Product status | New 100% |
WATER TO GLYCOL RATIO FOR USE IN CHILLER COOLING PROCESS
Calculating the correct ratio of glycol to water in a refrigeration system. Depends on the coldest temperature you need during operation. If the refrigeration system is used indoors, where there is a lower chance of freezing. The amount of glycol required will be significantly less than glycol chiller used outdoors. It is very important to use the correct ratio of glycol to water in the refrigeration system. Adding too much glycol will result in the system operating inefficiently. However, not enough glycol can cause the system to freeze. This can cause pipes to burst and even destroy the refrigeration evaporator.
| GLYCOL RATIO | WATER RATIO | COLDEST TEMPERATURE |
| 16% | 84% | 0 °C |
| 24% | 76% | -5 °C |
| 32% | 68% | -10 °C |
| 40% | 60% | -15 °C |
| 45% | 55% | -20 °C |
| 50% | 50% | -25 °C |
| 55% | 45% | -30 °C |
ANALYZE THE ADVANTAGES OF GLYCOL WATER CHILLER
One of the advantages of GLYCOL chillers is the ability to cool water and glycol solution at the same time. Glycol solution is a liquid refrigerant with a high heat capacity. Allows to maintain a stable temperature and meet the strict requirements of industrial processes. When using GLYCOL chillers. Users can adjust the mixing ratio of water and glycol solution to create an optimal cooling environment for each specific application.
GLYCOL Chillers provide high performance and reliability in the refrigeration process. With advanced compressors and refrigeration systems. GLYCOL Chillers can quickly reach the desired temperature. Maintain stability during operation. This ensures that industrial processes such as production, storage and transportation are carried out efficiently and safely.
Besides, GLYCOL water chiller also designed to save energy. With advanced technology and intelligent control system. GLYCOL Chiller uses inverter technology to meet each current cooling requirement. This helps to minimize energy waste and save operating costs during use.