Industrial Refrigeration Systems – Design, Manufacture and Installation

Industrial refrigeration system is the combination of cooling equipment that serves production and storage at plant scale — different from domestic air conditioning in capacity, in refrigerant and in the way it is operated. Tan Long designs, manufactures the equipment and installs turnkey industrial refrigeration systems for seafood, food and beverage processing plants and logistics cold stores — 29 projects delivered since 2005.

What an industrial refrigeration system is made of

Central NH3 compressor room for AJ Total Long Hau cold storage, installed by Tan Long.
A panoramic view of the NH3 central compressor room, meeting high safety standards, at the AJ Total Long Hau cold storage facility.

A complete industrial refrigeration system has four functional groups. Missing one, or sizing one wrongly, is the most common reason a system never reaches its design temperature.

ClusterFunctionMain equipment
Compression groupCompresses the refrigerant from low to high pressure — the heart of the systemScrew compressors, reciprocating compressors
Condensing groupRejects heat to the environmentEvaporative condenser, cooling towers
Expansion and receiver groupDrops the refrigerant pressure, stores it and separates liquidExpansion valves, pressure vessel, refrigerant pumps
Evaporating groupAbsorbs heat — where the usable cooling is actually producedCondenser, IQF conveyor, contact freezer, air blast freezer

Beyond these four groups there is the control system (electrical cabinet, SCADA), pipework, valves, and the insulated envelope (cold storage panel, cold storage door).

Classified by refrigerant

MYCOM screw compressor unit for NH3 refrigeration system at NECS cold storage facility, constructed by Tan Long.
High-capacity MYCOM screw compressor units, imported directly from Japan, are being used in the NECS cold storage project.

The refrigerant determines the efficiency, the running cost and the safety requirements of the whole system. It is the most important technical decision in the investment.

MediumSuited toKey characteristics
NH3 (Ammonia)Large plants running continuouslyHighest efficiency, lowest running cost, needs a dedicated machine room and safety procedures
Freon (R404A, R507)Small and medium stores, stand-alone unitsSimple to install, no dedicated machine room needed, higher refrigerant cost
CO2 (R744)Very low temperature ranges, cascade systemsVery high working pressure, safer than NH3 in occupied areas
GlycolIndirect cooling loads, workshop air conditioningA secondary heat transfer fluid, not a primary refrigerant

Many plants use a combined multi-refrigerant system to optimise cost across each temperature band. Tan Long has delivered a combined CO2, NH3 and R404 configuration at Lotte F&G Vietnam.

Classified by application

For large-scale industrial distribution centers and projects, central NH3 refrigeration systems with pump-assisted liquid supply are integrated with other solutions. ASRS smart cold storage with high-rise automation. and Cold storage logistics distribution This helps optimize the power consumption of the 35%.

System typeOperating temperatureFor use with
Individual quick freezing (IQF) systems-35°C to -40°CFreezing shrimp, fish and vegetables individually in 8–15 minutes
Air blast freezing tunnels, contact plate freezers-35°C to -40°CBlock and tray freezing
Frozen storage-18°C to -25°CStoring finished frozen product
Cool storage0°C to +5°CStoring fresh raw material, vegetables and dairy
System flake ice machine—Supplying ice to preserve raw material at intake and pre-processing
Workshop air conditioning+12°C to +18°CKeeping the processing area within food hygiene conditions
Water cooling system—Chilling wash water and process water

A typical seafood processing plant runs four to six of these at the same time, all served by one central compressor pack. Zoning the cooling load sensibly is what decides the electricity bill later on.

Three common mistakes when investing in an industrial refrigeration system

The control panel and PLC for the refrigeration system were installed by Tan Long.
Central control panel with integrated Siemens/Mitsubishi industrial PLC.

Across 29 projects, these are the three errors that cost investors the most — and all three happen before the contract is signed.

  • Sizing the load by floor area instead of by processing capacity. Two rooms of the same size but with different throughput and different incoming product temperature need very different cooling capacity. Get this step wrong and everything downstream is wrong with it.
  • Comparing quotations that do not cover the same scope. A cheaper quotation has usually cut the safety scope, cut the control scope, or specified lower-capacity equipment. Ask for an itemised breakdown so the comparison is like for like.
  • Leaving no room for expansion. It is normal for a plant to raise output after two or three years. If the compressor pack and the pipework leave no headroom, adding capacity later often costs more than the original investment.

What Tan Long's scope covers

Tan Long delivers the whole package, without separating design from execution:

  • Site survey and load calculation based on the plant's actual processing capacity
  • System design — selecting the refrigerant, the compressor configuration, the cooling load zoning and the machine room layout
  • Equipment manufacturing at the plant in Duc Hoa 1 Industrial Park, Tay Ninh (formerly Long An): IQF freezer conveyors, contact plate freezers, air blast freezers, flake ice machines, evaporative condensers
  • Supply of imported equipment — Mycom compressors, Güntner air coolers, Danfoss valves
  • Installation, commissioning and acceptance
  • Scheduled maintenance and fault rectification, including systems installed by other companies

Manufacturing its own equipment is the main difference from the trading contractor model. At Kyokuyo Vina Foods, 17 of the 33 main equipment sets were built by Tan Long itself.

Refrigeration Systems Technology Specialist

Chief Advisor: Engineer Nguyen Toan Thinh

Tan Long's Technical Director has over 20 years of expertise in designing thermodynamic schematics, optimizing two-stage NH3/Freon compression systems, and energy-saving heat recovery systems.

Consulting on Compressor Selection & Cost Estimation for Complete Industrial Refrigeration Systems

Tan Long provides a complete package, from design and self-manufacturing of pressure vessels/condensers to installation and transfer of safe operation technology.

Frequently Asked Questions

What is industrial refrigeration system?

An industrial refrigeration system is the combination of cooling equipment serving production and storage at plant scale, made up of four main groups: compression, condensing, expansion and evaporation. Unlike domestic air conditioning, an industrial refrigeration system uses refrigerants such as NH3 or CO2, has a capacity from several hundred kW upwards and runs continuously.

How does industrial refrigeration differ from ordinary air conditioning?

In three ways: capacity (hundreds to thousands of kW against a few kW), refrigerant (NH3 and CO2 rather than domestic refrigerant gas), and operating temperature (down to -40°C rather than +16°C). An industrial refrigeration system also needs a dedicated machine room, safety systems and a trained operating team.

Which refrigerant should a plant choose?

It depends on the size of the cooling load and on the site conditions. NH3 is the most economical for a large plant running continuously. Freon suits small and medium stores, or stand-alone units. CO2 is used for very low temperature ranges or cascade systems. Many plants use a combined multi-refrigerant system to optimise cost across each temperature band.

Which refrigeration systems does a seafood processing plant need?

Usually four to six at once: IQF quick freezing (-35°C to -40°C), air blast freezing tunnels or contact plate freezers, frozen storage (-18°C to -25°C), chiller rooms (0°C to +5°C), a flake ice plant for raw material intake, and air conditioning for the processing area. All of them run off one central compressor pack.

What determines the investment cost of an industrial refrigeration system?

Mainly the total cooling load, the required temperature range, the number of different temperature zones, the refrigerant selected and the level of automation. The load must be calculated from actual processing capacity, not from floor area — that mistake is the common reason a system never reaches its design temperature. Tan Long surveys the site before quoting.

Which industrial refrigeration projects has Tan Long delivered?

29 projects in Vietnam, covering seafood, food and beverage processing plants and cold chain logistics centres. The largest are a 30,000-pallet cold store at Meito Vietnam and a 12,000 MT frozen store at Frescol Tuna Vietnam. See the full project list.

Request advice and an industrial refrigeration quotation

Tan Long surveys the site, calculates the cooling load from actual processing capacity and quotes for the complete package. Call 0933 357 058 (Mr. Thinh) or send a quotation request.