Cold storage: Classification of systems and temperature standards according to product groups.

Cold storage Cold storage for preservation is a system of insulated buildings that maintains temperatures from 15°C (59°F) down to -45°C (-49°F) to keep food, pharmaceuticals, and agricultural products in a stable state according to the standards of each type of product. This system plays a central role in the cold chain of the food processing, agricultural and aquatic product export, and pharmaceutical distribution industries in Vietnam.

By operating temperature, cold storage falls into 3 main types: chill rooms (0°C–10°C), frozen stores (−18°C to −25°C) and blast freezing rooms (−35°C to −45°C). Each product group, from meat, seafood and fruit and vegetables to pharmaceuticals and vaccines, has its own standard temperature and humidity range. A cold room is built from insulation panel PU/EPS, cold room doors and an industrial compressor and evaporator system.

With over 20 years of experience in designing and constructing industrial refrigeration systems, the Tan Long team has compiled the following specialized knowledge to help businesses understand cold storage standards, from system classification and standard temperature charts for different product types to structure and criteria for selecting suitable contractors.

Cold storage: Classification of systems and temperature standards according to product groups.
Cold storage: Classification of systems and temperature standards according to product groups.

Content

What is cold storage? What are the principles of cold storage?

Cold storage is an insulated building system that uses industrial refrigeration equipment to maintain temperatures from 15°C (59°F) down to −45°C (−49°F). This system keeps food, pharmaceuticals, and agricultural products in a stable state, extending their shelf life according to the specific standards of each product type.

Cold storage facilities differ from household freezers or refrigerated containers in scale and structure. They are permanent structures, utilizing 50–200 mm (2–8 inches) thick insulated panels and high-capacity refrigeration systems operating on NH3 (ammonia) or R404A refrigerants. Storage capacities range from tens to thousands of cubic meters, far exceeding 20–40 foot refrigerated containers in terms of temperature control and compliance with HACCP standards.

The fundamental principle of cold storage systems is based on thermodynamics: low temperatures inhibit the activity of degrading enzymes and reduce the growth rate of microorganisms. At 0°C (32°F), bacterial activity is reduced. At −18°C (0°F), most microorganisms stop multiplying.

The vapor compression refrigeration cycle, with an evaporator absorbing heat from the warehouse space and a condenser dissipating it, maintains this temperature range continuously 24/7. Based on operating temperature and type of goods stored, cold storage facilities are classified into various types.

How are cold storage facilities classified according to temperature?

Cold storage Storage is divided into three main types according to temperature: chilled storage (0°C–10°C / 32°F–50°F), frozen storage (−18°C to −25°C / 0°F to −13°F), and quick-freezing storage (−35°C to −45°C / −31°F to −49°F). Each type serves different product categories and requires different insulation.

Warehouse typeTemperature (°C)Temperature (°F)Humidity (%)Sector servedPanel (mm)
Cool storage0 to 1032 to 5085–95Vegetables, milk, pharmaceuticals, fresh flowers50–75
Frozen storage−18 to −250 to -1390–95Seafood, meat, ice cream, frozen foods100–150
Freezer-35 to -45-31 to -4990–95Exported seafood, IQF, deep processing150–200

What temperature range does a cold storage warehouse operate within?

Cold storage maintains a temperature of 0°C–10°C with a humidity of 85–95°F, suitable for fruits and vegetables, fresh milk, pharmaceuticals, and fresh flowers. High humidity in cold storage limits wilting and dehydration of products. Cold storage systems are commonly found in supermarkets, distribution centers, and food processing plants. Pharmaceutical cold storage, in particular, requires tighter temperature control in the range of 2°C–8°C (36°F–46°F), along with a continuous monitoring system.

What temperature is required in a freezer to preserve goods?

Freezer storage facilities maintain goods at -18°C to -25°C for extended periods, ranging from 6 to 18 months depending on the product type. The insulated panels are 100–150mm (4–6 inches) thick and incorporate an automatic defrosting system to prevent ice buildup on the evaporator coils. Main applications include frozen seafood, pork/beef/chicken, processed foods, and ice cream. Condensate from the defrosting process must be drained outside the facility via a drainage system with an odor trap.

What are the outstanding features of quick-freezing and ultra-cold storage facilities?

Freezer Blast freezers rapidly lower product temperature from room temperature to -35°C to -45°C in 2–4 hours. This is the key difference from cold storage: blast freezing lowers temperature quickly, while cold storage maintains a stable temperature. The two systems typically operate in a continuous cycle, passing products through blast freezers or IQF conveyor Before transferring to the freezer storage area, the freezer insulation panels are 150–200 mm (6–8 inches) thick, using PU with a density of 38–42 kg/m³ to ensure insulation performance. Each type of freezer has its own standard temperature and humidity range for the specific goods stored inside.

What are the temperature and humidity standards for each type of goods?

Each product category has its own standard temperature and humidity range for cold storage. Fresh food requires -18°C to -22°C (0°F to -8°F). Vegetables and fruits are stored between 0°C and 12°C (32°F to 54°F). Pharmaceuticals and vaccines are controlled within the range of 2°C–8°C (36°F–46°F) according to GDP standards. The table below summarizes the standards for 10 common product categories.

Product group°C°F%BQ timeWarehouse typeTechnical notes
Beef/Pork/Chicken-18 to -220 to -890–956–12 monthsFreezingVacuum packaging extends shelf life by 3–6 months.
Seafood-20 to -25-4 to -1390–956–18 monthsFreezingExport to Japan/EU: -25°C. IQF freezing: -40°C
Milk & dairy products2 to 636 to 4380–857–30 daysCool storageSeparate from products with strong odors.
Leafy vegetables0 to 432 to 3990–987–21 daysCool storageHigh humidity reduces wilting and dehydration.
Temperate fruits-1 to 430 to 3985–951–6 monthsCool storageApples, pears, grapes. Control ethylene.
Tropical fruit8 to 1346 to 5585–9514–60 daysCool storageBananas, mangoes, durians. NOT below 10°C
Seeds2 to 836 to 4640–6012–36 monthsCool storageLow humidity maintains germination rates >90%
Pharmaceuticals2 to 836 to 4645–65According to the manufacturerCool storageGDP/GSP. Maximum deviation ±1°C
Vaccine2 to 836 to 4645–65According to the manufacturerCool storageWHO PQS. Data logger every 5 minutes
Industrial chemicals5 to 1541 to 59Depending on the typeDepending on MSDSCool storageRefer to the MSDS for each type.

What storage conditions are required for fresh food?

Meat, seafood and dairy account for 60–70% of cold storage demand in Vietnam. Seafood needs lower temperatures than meat because of its higher water content (70–80% versus 60–70%), which makes enzymes break it down faster. Products exported to Japan and the EU require −25°C with cold chain traceability. On export seafood cold store projects, the Tan Long team designs the NH3 refrigeration systems to hold −25°C with a deviation of ≤1°C between zones in the room.

Seafood is stored at -25°C to meet export standards and maintain product quality.
Seafood is stored at -25°C to meet export standards and maintain product quality.

What are the storage standards for agricultural products and fruits?

Leafy vegetables (lettuce, cabbage, cilantro) are optimally stored at 0°C–4°C (32°F–39°F) and humidity of 90–98 LTP3T. Temperate fruits such as apples, pears, and grapes should be kept at -1°C to 4°C and require ethylene gas control to extend shelf life. However, tropical fruits including bananas, mangoes, and durians should NOT be stored below 10°C (50°F); excessively low temperatures cause chilling injury: the fruit flesh turns brown and the flavor changes. This is a common mistake in operating cold storage for agricultural products. Seeds, on the other hand, require the opposite: a temperature of 2°C–8°C but low humidity of 40–60 LTP3T to maintain a germination rate above 90 LTP3T.

What technical specifications are required for pharmaceuticals and vaccines?

Pharmaceuticals and vaccines require separate, controlled cold storage within a range of 2°C–8°C (36°F–46°F) with a maximum deviation of ±1°C. GDP (Good Distribution Practice) and GSP (Good Storage Practice) standards regulate transportation, storage, and temperature monitoring. For vaccines, the WHO PQS (Performance, Quality and Safety) standard requires a data logger to record temperature every 5 minutes, along with an SMS/email alert system when the threshold is exceeded. In pharmaceutical cold storage facilities, Tan Long installs an automatic temperature monitoring system to ensure deviations do not exceed ±1°C, in accordance with GDP standards. To maintain this temperature range stably, the cold storage facility needs to be constructed with appropriate insulation panels, doors, and refrigeration systems.

What are the components of a cold storage warehouse?

The structure of a cold storage facility consists of three main groups: insulation panels (determining insulation efficiency), cold storage doors (controlling cold loss during opening/closing), and the refrigeration system (maintaining a stable temperature). The quality of materials determines the efficiency and lifespan of the facility.

How do PU and EPS insulation panels differ in performance?

Insulated panels are the most important component in the construction of cold storage facilities. The two most common types on the Vietnamese market are Polyurethane (PU) and Expanded Polystyrene (EPS).

CriteriaPU PanelEPS PanelUnitNote
Density38–4215–25kg/m³PU is heavier and harder.
Thermal conductivity0.0220.034W/mKPU insulates 35–40% better
Common thicknesses50/75/100/150/20050/75/100mmPU has a wider range of thicknesses.
Life expectancy20–2510–15yearsPU closed-cell offers good moisture resistance.
Comparative pricing30–40% higherFacility—EPS is suitable for cold storage and budget-conscious customers.

PU panels are suitable for cold storage and freezing due to their low thermal conductivity (0.022 W/mK) and high moisture resistance of their closed-cell structure. EPS panels are suitable for cold storage when budget is limited, although their insulation performance is lower (35–40%) compared to PU at the same thickness.

What is the role of warehouse doors and industrial compressor units?

Cold storage doors come in three main types: sliding doors for industrial warehouses with forklift access, hinged doors for smaller warehouses with infrequent opening, and quick open and close door Rapid doors for loading and unloading areas reduce cold air loss by up to 70% compared to conventional doors.

A refrigeration system comprises 3 core equipment groups. Compressors (Bitzer, Copeland, Mycom): screw type for large capacities above 50 HP and piston type for small rooms below 50 HP. Evaporative condenser (evaporative condenser) rejects heat efficiently in Vietnam's hot, humid climate, combining condensing and heat rejection in one unit and reducing pipework and water pump power compared with a shell-and-tube condenser plus cooling tower.

Industrial unit coolers consist of: fish bone condenser For freezer storage and fan-assisted cooling units for cold storage. Refrigerant NH3 (ammoniaR404A/R507 is used for industrial warehouses over 500m³, while R404A/R507 is for smaller-scale warehouses. A suitable structure is only a necessary condition; the cold storage warehouse must also meet technical standards regarding temperature, humidity, and safety.

What standards must a cold storage facility meet after installation?

After installation, cold storage facilities must meet standards regarding temperature and humidity control, stacking methods, and refrigeration safety. These parameters directly affect storage quality and long-term operating costs.

CriteriaStandard valueUnitNote
Temperature difference between zones≤2°CMeasured using temperature mapping.
Clearance between goods and walls≥150 (6 inches)mmEnsure airflow
Clearance between goods and ceiling≥300 (12 inches)mmAirflow from the cooling unit
Food certificationHACCP, ISO 22000—Mandatory for food exports
Pharmaceutical certificationGDP, GSP, WHO PQS—Mandatory for pharmaceutical warehouses.
Defrosting2–4 times/day—Automatic via timer or sensor
Condensate drainageDischarged outside the store—It has a water trap to prevent odors.

Meeting the standard at handover is only the start. Holding it requires the right operating and maintenance routine.

How to operate and maintain a cold storage facility effectively?

Operating a cold storage facility requires regular maintenance to maintain equipment performance and lifespan. Common maintenance cycles include: monthly for the evaporator (defrosting, cleaning the heat exchanger fins, checking the fan), every 3–6 months for the compressor (measuring current, checking oil level, gas pressure), and annually for the entire system (temperature mapping of the entire facility). The door seal can be inspected using the A4 paper test; if the paper easily peels off when the door is closed, the seal needs replacing.

However, many operational errors stem from a lack of knowledge or improper initial design. Below are common errors and how to prevent them.

Perform regular maintenance to ensure the cold storage facility operates smoothly, reliably, and efficiently in terms of energy consumption.
Perform regular maintenance to ensure the cold storage facility operates smoothly, reliably, and efficiently in terms of energy consumption.

What are the common problems encountered when operating a cold storage facility, and how can they be prevented?

Cold storage operational errors typically occur in three areas: temperature control, equipment maintenance, and product stacking. Early detection helps reduce repair costs and prevent product damage.

Common errorsCauseHow to avoid them
Uneven temperatures in the warehouse.Line up against the wall, blocking the airflow.Maintain a row-to-wall distance of 150mm (6 inches), aligning with the airflow.
The evaporator coil is covered in too much frost.Defrost timer set wrongly, door gasket not sealingAdjust the defrost cycle 2–4 times/day, and replace the gasket regularly.
The temperature rose suddenly.The door was left open for too long (>5 minutes), or the door was not properly sealed.Install PVC strip curtains, quick-opening doors, and check the seals.
Condensation on panelsPanel gaps greater than 1mm indicate insufficient insulation.Silicone sealant, panel thickness check.
Refrigerant leaksPoor weld quality, pipeline vibration.Regularly check for leaks using a leak detector and solder with N₂ purge.

In maintenance work cold storage for food preservation, The Tan Long team noted that the alignment of the walls, blocking airflow, accounted for 40%. In cases of uneven temperatures, simply adjusting the spacing between the walls could resolve the issue. Many errors stem from inappropriate initial design and installation. Choosing an experienced contractor helps reduce this risk.

How to choose a reputable cold storage design and installation contractor?

Selecting a cold storage contractor requires evaluating seven criteria: industry experience, equipment manufacturing capabilities, reference projects, warranty and maintenance services, 24/7 emergency hotline, and technical certifications.

CriteriaQuestions to ask the contractorMinimum value
Industry experienceHow many years have you been in operation? Do you have any projects in the same industry?≥10 years, same scale
Manufacturing capabilityDo you have a factory for manufacturing equipment or just for assembly?We have our own factory.
Reference projectsNumber of projects? Are there case studies?≥30 projects
WarrantyWhat is the warranty period for the refrigeration system? The panels?12–24 months (cold), 10 years (panel)
Regular maintenanceMaintenance frequency? Is there a 24/7 hotline?3–6 months, 24/7 hotline
CertificationISO 9001? HACCP? Technical certification?ISO 9001, HACCP
Design capabilityDo you have a team of engineers? CAD drawings? Cold load calculations?Dedicated engineering team

Tan Long is one of the few companies in Vietnam that simultaneously meets all seven criteria: over 20 years of experience, a manufacturing plant in Tay Ninh (formerly Long An), HACCP certification, and over 100 completed projects for businesses such as Lotte, CP Vietnam, Kyokuyo, and Vietnam Clean Seafood. A list of typical cold storage projects is updated at tanlongvn.com/cong-trinh.

Frequently Asked Questions about Cold Storage

What is the difference between cold storage and freezer storage?

Cold storage maintains goods at the set temperature (-18°C to 10°C) for extended periods. Freezing quickly lowers the temperature from room temperature to -35°C to -45°C within 2–4 hours. The two systems typically operate in a continuous cycle: freezing first, then storage.

Is a separate cold storage facility necessary for pharmaceuticals?

Yes. Pharmaceuticals require temperature control of 2°C–8°C, continuous monitoring with data loggers recording every 5 minutes, and GDP/GSP certification. Pharmaceutical warehouses cannot be shared with food warehouses due to different hygiene and traceability standards.

What is the standard temperature for cold storage to preserve food?

Fresh and frozen foods: -18°C to -22°C (0°F to -8°F). Vegetables and fruits: 0°C to 12°C (32°F to 54°F). Milk and dairy products: 2°C–6°C (36°F–43°F). Specific temperatures depend on the type of product and storage time.

Do cold storage facilities consume a lot of electricity?

Electricity costs account for 40–60% of the operating costs of cold storage. High-quality PU insulation panels (with appropriate thickness for the temperature range) and a high-efficiency refrigeration system (COP ≥3.0) help reduce electricity consumption by 20–30% compared to standard systems.

Why is proactive quality control necessary starting from the cold storage selection stage?

Cold storage is a technical system that demands precision from sorting and design to operation. Understanding the standard temperature and humidity ranges for each product group, from seafood and agricultural products to pharmaceuticals, helps businesses choose the right type of warehouse and assess system quality. The warehouse structure, with its PU insulated panels, specialized doors, and industrial refrigeration system, determines the long-term performance of the 60–70%.

Choosing a contractor with over 10 years of experience, a manufacturing facility, and HACCP/ISO certification is a crucial step in ensuring stable operation and compliance with industry standards for cold storage facilities. Businesses needing technical advice on cold storage can contact our team of engineers. Tan Long Visit tanlongvn.com/lien-he to receive a suitable design proposal.

See also:

Related pages

Add Sidebar Widgets

Contact consultant

Tan Long's customers